Skip to content

Existing Customers Call 626-359-4550 Or Visit Customer Care

Come see us at GTF Expo in China!   July 10 – 12, 2024

Victoria Texas 501F Generates 24 MW Boost M501F GT

The MeeFog system provides wet compression downstream of an existing evaporative cooler for the M501F gas turbine. The Meefog skid has six pumps and provides six stages of fogging. Each stage produces a 4 MW power boost, resulting in a 24 MW total power boost.

Project Conditions:

Location: Victoria, Texas
Hot day conditions: 97° F with 76° wet bulb
Model: M501F Gas Turbine
Elevation: 118 feet
Mee’s scope of work: Turnkey except for control mods
Max power boost per GT: 24 MW

Fog System Design:

Cooling Stages: 6
Operating Pressure: 2,000 psi
Fog Droplet Size: 12 microns (D32)
MeeFog™ Nozzle Count: 1,950
Nozzle Flow Rate: 0.080 gpm per nozzle
Max. Skid Water Flow: 156 gpm
Max. Power Requirement: 6 x 50 HP

Learn More

Want to learn more about successful Meefog systems installation projects and case studies?

Other Related Blog Articles

MeeFog Adds 64MW of Power Augmentation to Mexican Power Plant

Case Study: To capitalize on new market opportunities arising from energy regulations in Mexico, the Tuxpan III......

Power Output Boost of 28 MW Using Wet Compression

Case Study: MeeFog wet compression systems fitted onto two Siemens SGT-5000FD2 gas turbines in the state of......

32 MW Power Boost On a Siemens Westinghouse W501FC

Project Profile: A power station in Mexico installed two MeeFog systems on a Siemens Westinghouse W501FC gas......