Enterprise. Mission Critical.
Efficiently condition and cool. Beneficial Change Is In The Air - Cooling by MeeFog™
Energy efficient Data Centers take advantage of free cooling and direct evaporative cooling many months of the year.
The Internet is having a major impact on the growth of information systems departments. The volume of servers and other hardware, the required support services, and the number of employees has also increased in parallel to the internet growth.
Larger data centers have more equipment, producing more heat, and need a dedicated humidification system to stabilize the fluctuation of relative humidity (RH). However, temperature and humidity control is often overlooked.
Inadequate humidification is a concern for data centers. Low humidity can lead to excess static electricity and lead to electrostatic discharge (ESD) resulting in fatal component damage. Large fluctuations in humidity can cause circuit boards to expand and contract, damaging circuitry.
Mee Industries answers these potentially harmful conditions by a process called adiabatic humidification. This process introduces a controlled amount of humidity into the air handling unit (AHU) or duct, reducing the potential buildup of electrostatic discharge and helps maintain overall temperature and humidity control.
With Mee fog humidifiers installed at your data center, computer equipment reliability is increased by monitoring relative humidity and is optimum for both equipment and personnel.
Savings in running costs and low maintenance routines means that a MeeFog system will typically pay for itself within one year.
Want proof?
We'll gladly supply a detailed power recovery report for your existing Purpose Built Data Center including:
- Installed MeeFog™ system cost
- Guaranteed Power Gain
- Predicted Process Gains Per Year
- Fuel Savings
- Payback Analysis
MeeFog™ System Benefits:
- Reduces electrostatic shock.
- Suspend airborne dust
- High quality, corrosion resistant system components.
- Low energy consumption.
- Cools and conditions.
- Easy to service and maintain.
- Ultra-fine fog droplets
- Stainless steel construction
- Flexible and easy to retrofit
- Easy to specify
- Guaranteed Results!
Featured Case Study
Data Center Cooling, Prineville, Oregon, USA
Mee Fog Humidifier Installation
Design and build an energy-efficient 147,000 sq. foot data center that can operate year-round without using mechanical cooling, even when summer temperatures reach 110°.
The Solution
Use a custom designed MeeFog system, consisting of 28 fogging units and more than 6600 nozzles to provide the exact levels of cooling and humidification.
Keep the equipment operating efficiently using evaporative cooling combined with outside air.
No need to purchase or operate expensive chillers.
Fog Nozzles in plenum use a mist eliminator made of a special synthetic fiber that is impregnated with an antimicrobial substance to inhibit the growth of bacteria.
When the Open Compute Project launched with it's first data center in Prineville, Oregon, it selected a system that uses both outside air and the cooling power of water. But in this case, it didn't involve pumping huge volumes of water through the data center, instead using the natural evaporative effect of the water to cool the air.
Learn More
Showcase
The MeeFog™ Rack
The highly reliable, robustly engineered MeeFog™ rack incorporates a system of high-pressure pumps, which pressurize demineralized water. This ultra-clean water flows through a network of stainless steel tubes and then through the revolutionary MeeFog™ nozzles. Each self-contained MeeFog™ rack includes a programmable logic controller (PLC) control system that allows the system to operate safely in automatic mode.
Mee Industries' unique turnkey installations are made possible by our proprietary high-pressure MeeFog™ racks, allowing the completion of installations with as little as 1-2 day outages.